Sahawatthanakit (1988) Co., Ltd.
SAHAWATTHANAKIT(1988) · Make It Smart
INSIGHTS

Insights & Industry Knowledge

Articles, news, and technical insights on construction materials, pallet racking, lubricants, and Thai industrial standards — sourced and cited from trusted references.

Machine-shop production team selecting cutting fluids and coolants for turning, milling and grinding operations

Choosing the Right Metalworking Fluid / Cutting Coolant — A Machine-Shop Field Guide: Neat Oil vs Soluble vs Semi-Synthetic vs Synthetic + Concentration Control (Refractometer), Sump Care & How to Lock In Drum Pricing

A field guide for machine-shop production and procurement teams: selecting the right metalworking fluid (MWF) by operation and material — neat/straight cutting oil for heavy-duty tapping/reaming/broaching, soluble oil for general work, semi-synthetic for balanced lubrication and cooling, synthetic for grinding and high speed, plus material-specific selection (steel/stainless/aluminium/cast iron), refractometer concentration control, pH/tramp-oil/bacteria sump management, mist health limits (NIOSH), and how to buy concentrate by the drum to lock in annual pricing.

metalworking fluidcutting fluidcoolant
Read more
Metal fabrication / machine-shop supervisor planning hot work, surface prep, coating systems, and machine lubrication with safety

Metal Fabrication / Machine-Shop Fit-Out and Maintenance Field Guide — Safe Hot Work to NFPA 51B + Fire Blankets · Sa 2.5 Surface Prep to ISO 8501 · ISO 12944 Coating Systems + Zinc-Rich Primer · DFT/Holiday Inspection · Machine Lubrication + ISO 8573 Compressed Air + Electrical Safety + How to Lock In Material Pricing

Field guide for metal fabrication / machine-shop / structural-steel workshop owners and supervisors: plan the whole workshop by function — control hot work (weld/cut/grind) per NFPA 51B with the right fire-blanket grade (EN 1869/FM 4950), prepare steel to Sa 2.5 per ISO 8501 before coating, choose a corrosion coating system per ISO 12944 by environment class (C1-CX) with zinc-rich primer/powder/liquid, inspect dry film thickness (ISO 19840/SSPC-PA2) and holidays, lubricate machinery (hydraulic/gear/grease) + monitor oil/bearing condition, control compressed-air quality (ISO 8573) for abrasive blasting and spraying, and manage electrical safety (arc flash NFPA 70E) + cranes/hoists (ASME B30) — plus how to standardize materials to lock pricing and delivery.

metal fabricationmachine shopfabrication
Read more
Food and cold-storage plant engineer planning refrigeration, hygienic floors, food-grade lubricants, and water/air systems for a food production line

Food & Beverage and Cold-Chain Factory Fit-Out and Maintenance Field Guide — Select Refrigeration/Refrigerants to ASHRAE 15/EN 378/ISO 5149 · Hot-Washdown PU-Cement Floors · NSF H1/ISO 21469 Food-Grade Lubricants · Food/Pharma Corrosion Coatings · Boiler-Cooling-RO Water · ISO 8573 Food-Contact Air · Safe Hot Work + How to Lock In Material Pricing

Field guide for food & beverage and cold-storage plant owners and engineering/maintenance teams: plan the whole factory with food safety governing every choice — select the refrigeration system/refrigerant by temperature band and refrigerant safety per ASHRAE 15/EN 378/ISO 5149, handle ultra-low/freeze-dry and retrofit of legacy R-13B1, lay PU-cement floors that survive hot-water washdown and food acids in wet zones, choose NSF H1/ISO 21469 food-grade lubricants for points above food, coat walls/tanks to food/pharma grade, control process water (boiler/cooling/RO/CIP) and cooling-tower legionella, control food-contact compressed-air quality to ISO 8573, and control hot work during repair/install per NFPA 51B — plus how to standardize materials to lock pricing and delivery for the whole plant.

food factoryfood and beveragecold storage
Read more
Warehouse manager planning racking, epoxy floor, rooftop solar, and safety equipment for a distribution center

Warehouse & Distribution Center (DC) Fit-Out and Maintenance Field Guide — Select Racking to AS 4084/EN 15512 · Epoxy/PU Floors · Steel Corrosion Protection · Rooftop Solar · Forklift Oils · Cold Storage · Safe Hot Work + How to Lock In Project Material Pricing

Field guide for warehouse and distribution-center (DC) owners and maintenance teams: plan the whole building by function — choose a racking system (Selective/Drive-In/Push-Back/Cantilever) to AS 4084/EN 15512, design for seismic loads (DPT 1311/ASCE 7), guard rack uprights and inspect annually per EN 15635, coat floors (epoxy/PU/PU-cement) to the load, protect steel from corrosion, put solar on the roof only after a structural load assessment, select forklift/MHE hydraulic-gear-grease oils, run cold storage, and control hot work during rack install/expansion per NFPA 51B — plus how to standardize materials to lock project pricing and delivery.

warehousedistribution centerDC
Read more
Shipyard maintenance team selecting anti-corrosion paint systems, zinc anodes, and fire blankets for coastal steel structures

Marine & Shipyard Corrosion Protection Field Guide — Choose the Whole System: Surface Prep (Sa 2.5) · ISO 12944 C5-M/CX/Im2 Paint Systems · Cathodic Protection (Anode/ICCP) · Safe Hot Work + How to Lock In Project Material Pricing

Field guide for shipyard, jetty, and coastal steel-structure maintenance: plan corrosion protection across the whole asset by zone (atmospheric/splash/immersed/buried) — abrasive blast Sa 2.5 per ISO 8501, select an ISO 12944 paint system for C5-M/CX and immersed Im2, design cathodic protection with sacrificial anodes (zinc/aluminium/magnesium) vs ICCP per DNV-RP-B401/ISO 12696, control hot work in confined spaces per NFPA 51B, and lubricate marine machinery — plus how to standardize materials to lock project pricing and delivery.

shipyardmarine corrosioncorrosion protection
Read more
HVAC contractor selecting refrigerant cylinders of multiple grades for installation and maintenance work

Pick the Right Refrigerant for the Job — A Contractor's Field Guide: Charge Tables by System (Split / VRF / Chiller / Cold Room / Ice Plant / Auto) + R-22/R-404A Replacements + How to Source Cylinders Fast

Field guide for HVAC/R contractors in Thailand: choose the correct refrigerant by actual system type (residential/commercial Split & VRF, chillers, MT/LT cold rooms, ice plants, automotive, ULT) + R-22/R-404A drop-in & retrofit table + compressor oil you must change with it (MO/POE) + how to source refrigerant fast at contractor/fleet pricing.

RefrigerantHVAC contractorR32
Read more
Industrial centrifugal pump installed in a chemical plant with mechanical seal and VFD drive in Thailand

Selecting an Industrial Process Pump + Preventing Cavitation (NPSH): Centrifugal vs Positive Displacement, BEP, and VFD Energy Savings per ANSI/HI–ISO for Thai Plants

Buyer's guide to industrial process pumps: differentiate Centrifugal vs Positive Displacement → calculate NPSHa to prevent cavitation → operate within BEP (70–120%) → cut electricity with VFD (Affinity Laws) → supplier checklist + ANSI/HI–ISO 13709/API 610/API 682 standards for plants in Thailand.

Industrial PumpCentrifugal PumpPositive Displacement
Read more
Industrial water treatment system with softener tanks, RO membrane skid, and pH control for a factory in Thailand

Industrial Water Treatment: Boiler Feedwater, Cooling Water, RO/Process Water, and Wastewater Compliance — Selection + Thai Effluent/ASME/WHO Standards for Plants

Buyer's guide to industrial water treatment: separate boiler feedwater–cooling water–process/RO water–wastewater streams → choose the right treatment process for each stream → worked cycles-of-concentration example → contractor checklist + ASME/ABMA/WHO/Thai DIW/PCD standards for factories in Thailand.

Industrial Water TreatmentBoiler FeedwaterCooling Water
Read more
Fleet maintenance team selecting diesel engine oil, hydraulic oil, and grease of multiple grades for trucks and heavy equipment

Fleet & Heavy-Equipment Lubrication Field Guide — Choose Every Oil on the Machine: Diesel Engine (API CK-4) · Gears/Final Drive (API GL-5) · Hydraulics · Grease + Change Intervals by km/Hours and How to Lock In Fleet Pricing

Field guide for fleet maintenance and procurement: a whole-machine lubrication map for trucks/prime movers, excavators, cranes, loaders, and mining equipment — diesel engine API CK-4/CJ-4 SAE 15W-40, hypoid final drive API GL-5, severe-duty hydraulics ISO VG 46/68, NLGI 2 EP grease + crane wire-rope grease — change intervals by kilometre/engine-hour + oil analysis to extend drains safely, and how to standardize grades to lock in annual fleet pricing.

fleet lubricationtruck engine oilheavy equipment
Read more
Industrial counterflow induced-draft cooling tower with water treatment system for factories in Thailand

Industrial Cooling Tower Selection + Water Treatment: Types, Range/Approach, and Scaling/Corrosion/Legionella Control per CTI/ASHRAE 188 for Thai Plants

Buyer's guide to industrial cooling towers: compare open-circuit vs closed-circuit, counterflow vs crossflow, induced-draft vs forced-draft → calculate Range/Approach → water treatment for Scaling/LSI, Corrosion, Biofouling, and Legionella per CTI ATC-105 and ASHRAE Standard 188 for plants in Thailand.

Cooling TowerWater TreatmentLegionella
Read more
Industrial cold storage room with evaporator and PIR sandwich panel for food and pharma plants in Thailand

Industrial Cold Room / Cold Storage: Chiller vs Freezer vs Blast Freezer + Refrigerant Selection + Cooling Load Calculation + EN 378/GDP Standards for Thai Food, Pharma & Logistics Plants

Buyer's guide to industrial cold storage: separate chiller (+2 to +8°C) / freezer (−18 to −25°C) / blast freezer → calculate real cooling load before sizing → compare refrigerants R-449A/R-448A/R-290/R-744/NH3 → choose PIR panel thickness → contractor checklist + EN 378/ISO 5149/GDP/HACCP standards for plants in Thailand.

Cold RoomCold StorageChiller Room
Read more
Solar panels on an industrial factory rooftop in Thailand

Solar Rooftop Factory Permits in Thailand 2026 — RG.4, ERC, Building Permit & Grid Interconnection

The latest guide to permitting a factory rooftop solar system in Thailand. After the 2024 ministerial regulation removed the RG.4 factory license, three steps remain: ERC license exemption (1,000 kVA threshold), building modification permit (160 sq.m threshold), and PEA/MEA grid interconnection under zero-export — with real documents and timeline.

Solar Rooftopโซลาร์รูฟท็อปSolar Permit Thailand
Read more
Comparison of factory rooftop solar investment models CAPEX, PPA and Leasing

Factory Rooftop Solar: CAPEX vs PPA vs Leasing — Which Investment Model Wins

A decision-ready comparison of the three rooftop-solar investment models for Thai factories: CAPEX (own it outright, one-time payment, 4–6 year payback, claim BOI + depreciation), PPA (developer funds it free, you buy the power at 20–40% below grid for 10–25 years, zero capex), and Leasing (fixed monthly payment, you keep all the power). Includes a side-by-side comparison table, a 10-year cash-flow example for a 100 kWp system, 5 deciding factors (budget/tax/roof ownership/risk/time horizon), and the 6 PPA contract clauses to read before signing (escalation, buyout, REC/carbon credits, performance, building-sale transfer) per ERC/BOI/MEA and TFRS 16.

solarppacapex
Read more
Cascade refrigeration system of a freeze dryer with ultra-low-temperature gauges and an R-508B refrigerant cylinder

Very-Low / Ultra-Low Temperature Refrigerant Retrofit — Replacing R-13B1 / R-503 / R-13 in Freeze Dryers & Cascade Systems with R-508B / ISCEON MO89, Done Right

A guide to very-low / ultra-low temperature (VLT/ULT) refrigerant retrofits for freeze dryers (lyophilizers), environmental chambers, blast freezers and cascade systems in Thailand: why R-13B1 (halon), R-503 and R-13 (CFC) are obsolete/unobtainable, the modern replacements R-508B and ISCEON MO89 across −40 to −80°C, the most-missed core of the job — changing compressor oil (mineral/AB → POE) and low-temperature oil return, how glide/azeotrope affects charging and the TXV, retrofitting both stages of a cascade, the correct procedure (recover → flush → change drier/seals → deep vacuum < 500 micron → charge by weight → pulldown), and why moisture is the deadly enemy at ULT — plus the high GWP of R-508B/R-23, lower-GWP options, and refrigerant import licensing via Thailand's DIW under Montreal/Kigali obligations.

refrigerantultvlt
Read more
Measuring and mitigating harmonics at a factory MDB with a power quality analyzer and active harmonic filter

Harmonics in Factories — Fix Overheating Transformers & Failing Capacitor Banks per IEEE 519 with Reactors / Filters / AHF

A guide to fixing harmonic distortion in Thai factories caused by VFDs/UPS/rectifiers: 6 warning signs (failing capacitor banks, overheating transformers/neutrals, nuisance breaker trips), the difference between THD-V / THD-I / TDD, the IEEE 519-2022 limits (THD-V 5% at 1–69 kV / 8% at ≤1 kV and TDD by Isc/IL), the mitigation ladder from cheap to costly (3–5% line reactor → passive filter → detuned capacitor → 12/18-pulse → Active Harmonic Filter), how to choose, and why you must run a 7-day Power Quality Audit per IEC 61000-4-30/4-7 before buying a filter — plus MEA/PEA implications and transformer K-factor derating per IEEE C57.110.

engineeringharmonicsieee-519
Read more
Cascade refrigeration system for a freeze dryer ice condenser in pharmaceutical and food lyophilization

Refrigeration System & Refrigerant Selection for Freeze Dryers / Lyophilizers — Buyer's Guide for Pharma, Food & Biotech in Thailand

How to select the right refrigeration system (single-stage, cascade, hybrid) and refrigerant for a freeze dryer ice condenser: calculate sublimation load → set cold trap temperature → compare R-23/R-508B/R-449A → supplier checklist. For pharmaceutical lyophilizers, food freeze-drying, and biotech operations in Thailand.

Freeze DryerLyophilizerRefrigerant
Read more
Rooftop lightning protection system with air terminals, down conductors and an earth test pit on a Thai factory

Factory Earthing & Lightning Protection — Designing to IEC 62305 / EIT to Stop Equipment Damage and Pass TOR & Utility Requirements

A practical guide to designing earthing (grounding) and lightning protection systems (LPS) for Thai factories and buildings: how safety earthing per IEC 60364 differs from lightning protection per IEC 62305, the IEC 62305-2 risk assessment that decides whether you even need an LPS (R1 vs RT), the four protection levels LPL Class I–IV (rolling sphere 20/30/45/60 m, mesh size, down-conductor spacing), Type A/B earth terminations, target ground resistance ≤5 ohm, fall-of-potential measurement, Wenner soil resistivity, TN-S/TN-C-S/TT earthing systems, coordinated SPD Type 1/2/3 per IEC 61643 to protect electronics, exothermic weld vs clamp connections, equipotential bonding and annual inspection — plus what it means for government TOR, utility (MEA/PEA) connection, and insurance conditions.

engineeringearthinggrounding
Read more
Electrician in arc-rated suit and face shield working at an MDB with an arc flash warning label

Arc Flash Safety — Hazard Assessment & Incident Energy Analysis to NFPA 70E / IEEE 1584, Choosing the Right PPE Category for Thai Factories

An arc flash guide for Thai factories: how arc flash differs from electric shock and why it's more dangerous (arc temperatures up to ~19,000°C plus blast), the two PPE-selection methods you must never mix — Incident Energy Analysis per IEEE 1584-2018 vs the NFPA 70E PPE Category table, what incident energy (cal/cm²) means, the 1.2 cal/cm² second-degree-burn threshold, the arc flash boundary, the PPE Category 1–4 table (4/8/25/40 cal/cm²), the Arc Flash Study workflow (short-circuit → coordination → calculation → labeling), reducing energy at source via the hierarchy of controls (de-energize + LOTO before PPE, relay/maintenance mode, arc-resistant switchgear, remote racking), arc-rated clothing (ATPV/EBT, IEC 61482) and NFPA 70E labels — plus what it means for Thai electrical-safety law, TOR, and insurance.

engineeringarc-flashnfpa-70e
Read more
Yellow rack column guards and an end-of-aisle barrier protecting uprights from forklift impact in a warehouse

Rack Protection — Column Guards / End Barriers / Row Guards per EN 15512, EN 15620 & EN 15635 to Cut Forklift Damage

A guide to selecting pallet-rack protection against forklift impact: column/upright guards, end-of-aisle barriers, guard rails, guide rails — EN 15512 (0.5 kN accidental horizontal force at up to 0.4 m), column guards ≥ 400 mm high absorbing ≥ 400 Nm, EN 15620 clearances, EN 15635 GREEN/AMBER/RED damage assessment + PRRS, and what a TOR must specify to prevent rack collapse in Thai warehouses.

warehouserackingrack-protection
Read more
A technician scanning a coated steel tank surface with a high-voltage spark holiday detector

Holiday / Pinhole Detection in Coatings — Wet Sponge vs High-Voltage Spark per NACE/AMPP SP0188 & ASTM D5162

A guide to detecting holidays/pinholes (invisible discontinuities) in protective coating films: choosing low-voltage wet sponge (thin film < 500 µm) vs high-voltage spark/DC (thick film > 500 µm) per NACE/AMPP SP0188, SP0490 and ASTM D5162 — setting voltage by DFT (too low misses holidays, too high burns the film), which work requires it (tanks/pipes/immersion/marine), mark-repair-retest, and what a TOR must specify.

paintholiday-detectionpinhole
Read more
A certified coating inspector examining the paint film on an industrial steel tank

Coating Inspectors: NACE/AMPP CIP vs FROSIO — Who Needs Certification, Levels 1/2/3, and TOR Requirements

A comparison of the two main coating-inspector certification schemes: NACE/AMPP CIP (Coating Inspector Program — Levels 1/2/3, after NACE merged into AMPP in 2021) vs FROSIO (the Norwegian scheme — competence levels I/II/III) — what each level can do, which projects need which level, recognition in Thailand and abroad, and what a TOR must specify (level, independence, hold points, reporting) so coating work can actually be accepted.

paintcoating-inspectornace
Read more
A technician measuring steel surface temperature and humidity with a dew point meter before applying protective coating

Coating Application Conditions — The 'Surface ≥ Dew Point + 3°C' Rule, RH < 85% per ISO 8502-4 & ISO 12944-7

A guide to environmental conditions during protective-coating application: steel surface must be at least 3°C above the dew point, relative humidity RH < 85% (per the TDS), surface temperature within the product's range — how to measure the 4 readings (air temp, RH, dew point, surface temp) per ISO 8502-4 and ISO 12944-7, why painting in humid/near-dew-point conditions causes peeling/blistering/flash rust, and what a TOR must specify for Thailand's humid climate.

paintdew-pointapplication-conditions
Read more
Capacitor bank panel for power factor correction in an industrial plant

Power Factor Correction for Factories — Stop Paying MEA/PEA's 56.07 Baht/kVAR Penalty with a Capacitor Bank

How to fix low power factor in a Thai factory: why MEA/PEA charge when kVAR exceeds 61.97% of kW (PF < 0.85) at 56.07 baht/kVAR, how to size a capacitor bank (Qc = P(tanφ1−tanφ2)), fixed vs automatic APFC, the harmonics trap from VFDs that needs a detuned reactor per IEEE 519 / IEC 61921, and the ROI that is usually under one year.

engineeringpower-factorcapacitor-bank
Read more
Protective coating application on structural steel per ISO 12944 in industrial work

ISO 12944 Protective Paint Systems for Steel — Selecting Corrosivity C2–CX, Durability, and Primer/Intermediate/Topcoat for Thailand

How to select a protective coating system for steel structures per ISO 12944: corrosivity categories C1–C5/CX (2017/2018 revision), durability ranges L/M/H/VH, matching zinc-rich primer + epoxy MIO + PU topcoat systems to dry film thickness (DFT) per category, mapping to Thai environments (urban plants vs coastal Map Ta Phut/Laem Chabang), and the spec mistakes TOR writers make most.

paintiso-12944corrosion
Read more
Assessing factory roof structure before rooftop solar panel installation

Can Your Factory Roof Take Solar? — Structural Load, the 20 kg/m² Rule, and Wind Uplift (มยผ. 1311) Before Installing PV

How to assess a factory roof before installing rooftop solar in Thailand: the dead load a PV system adds (panel + rails + ballast), the 20 kg/m² legal threshold (2023 ministerial regulation exempting it from a building-modification permit), the real weak point of metal-sheet roofs (purlins + fixings) vs concrete decks, wind uplift per มยผ. 1311-50 / AS-NZS 1170, and the checklist a licensed civil engineer must sign off.

solarrooftopstructural-load
Read more
Inspector measuring dry film thickness DFT with a gauge on coated steel

Inspecting & Accepting Industrial Coating Work — DFT per ISO 19840 / SSPC-PA 2, the 80-20 Rule, Adhesion and Holiday

A guide to coating inspection and acceptance: measuring dry film thickness (DFT) per ISO 2808, acceptance criteria of ISO 19840 (mean ≥ NDFT, every reading ≥ 80%, the 80-20 rule) vs SSPC-PA 2 (gauge → spot → area, 80-120%), pull-off adhesion per ISO 4624, holiday/pinhole detection per NACE/ASTM, degradation rating per ISO 4628, and what to put in a TOR so coating work can actually be accepted.

paintcoating-inspectiondft
Read more
Designing a galvanic cathodic protection system — current demand, anode mass and anode count

Designing a Galvanic Cathodic Protection System — Current Demand, Anode Mass & Anode Count (DNV-RP-B401 / ISO 12696)

A step-by-step guide to sizing a sacrificial-anode corrosion protection system — current density by environment, the anode mass formula (M = I·t·8760 / u·ε), anode count from current output, and the −850 mV / 100 mV decay criteria, with a worked example. References DNV-RP-B401, ISO 12696, NACE SP0169 / ISO 15589, ASTM B418.

Cathodic ProtectionCP DesignSacrificial Anode
Read more
Oil-free magnetic bearing centrifugal compressor compared with a screw compressor in a chiller plant room

Magnetic Bearing Compressor (Turbocor) vs Screw Compressor — 15-Year TCO for Thai Chillers

Comparing two chiller compressor types: oil-free magnetic bearing centrifugal (Danfoss Turbocor) versus positive-displacement screw — covering part-load IPLV efficiency, first cost, maintenance, oil-free vs oil-flooded, surge limits, and a 15-year TCO model at Thai electricity ~THB 4.5/kWh, with guidance for data centers, hospitals, malls and factories.

refrigerantturbocormagnetic-bearing
Read more
Comparison of string inverter, central inverter, microinverter and power optimizer on a factory solar roof

String vs Central vs Micro Inverter + Power Optimizer — Choosing Solar Inverter Architecture

Comparing four solar inverter architectures for Thai factory roofs and commercial buildings: string inverter, central inverter, microinverter and power optimizer (DC optimizer) — covering MPPT granularity, shading/mismatch tolerance, panel-level monitoring, rapid-shutdown safety, cost per watt, maintenance, standards IEC 62109 / IEC 62116 anti-islanding, and how to match the architecture to the job.

solarinvertermicroinverter
Read more
Solar carport structure with PV panel roof for commercial buildings and factories in Thailand

Solar Carport Structure Design — Wind Load Engineering per Thai DPT / AS/NZS 1170

A design guide for solar carport structures for Thai factories and commercial buildings — focused on wind uplift as the critical load, standards มยผ. 1311 (DPT) / AS/NZS 1170.2 / ASCE 7, balancing tilt angle against wind, vehicle clearance + EV charger, hot-dip galvanized steel for corrosion, foundations that resist overturning, and the building permit (Aor.1) + licensed-engineer sign-off requirement.

solarcarportwind-load
Read more
R-134a refrigerant cylinders and a replacement transition plan for cooling systems

When Is R-134a Phased Out? The Kigali Amendment Timeline and Replacement Plan for Thailand

A guide to the R-134a phase-down timeline: why R-134a wasn't banned under the original Montreal Protocol but falls under the Kigali Amendment (HFC phase-down), Thailand's HFC quota reduction schedule (DIW), EU F-Gas + MAC Directive, replacements R-1234yf (automotive) and R-513A/R-1234ze (chillers), plus a transition plan for factories and vehicles in Thailand.

refrigerantr134akigali-amendment
Read more
Inspecting solar panel degradation with EL imaging and IV curve for a Thai factory

PV Module Degradation — PID/LID Mechanisms, EL Imaging Measurement, and Warranty Claims in Thailand

A deep look at the degradation mechanisms that push solar panels past spec, especially in Thai conditions (heat + humidity + high voltage): LID, PID, LeTID, thermal cycling, microcrack/hotspot — with how to prove real degradation using IV curve flash test, EL (electroluminescence) imaging, IR thermography and Performance Ratio monitoring, PID prevention, and the evidence needed to claim warranty per IEC 61215 / IEC TS 62804.

solarpv-degradationpid
Read more
Glycol chiller secondary loop for a food processing plant with DX evaporator coil

Glycol Chiller vs DX Cooling for Food Plants — Choosing by ASHRAE 90.1 / Thailand BEC

Comparing two cooling architectures for food processing: DX (Direct Expansion) where refrigerant evaporates directly in the coil, versus a Glycol Chiller secondary loop using propylene glycol — covering refrigerant charge limits per ASHRAE 15 / EN 378, food-safety PG vs EG, energy performance per ASHRAE 90.1 / BEC, glycol concentration selection, and how to match the system to Thai food plant requirements.

refrigerantglycol-chillerdx-cooling
Read more

Saha Industrial Insights รายสัปดาห์

ทุกอาทิตย์: 1 บทความเทคนิคใหม่ + 1 case study + เคล็ดลับ ไม่มี spam ยกเลิกได้ทุกเมื่อ