These three grades cover jobs the common refrigerants can't: R417a = an A1 (non-flammable) drop-in for R-22 that works on the existing system without changing the compressor — a bridge before investing in new R-32 gear. R454C = an A2L HFO/HFC blend with very low GWP for new refrigeration/heat-pump equipment (an R-410a-class alternative). R123 = an HCFC for low-pressure centrifugal chillers, replacing R-11 in legacy service. All three are made-to-order (quote-only) — send the machine spec and volume for a quote.
The main refrigerant grades (R-32, R-410a, R-134a, R-404a) cover most jobs, but three specific jobs can't use them — and their grades are hard to find on the open market: replacing R-22 without rebuilding the unit, very-low-GWP new refrigeration equipment, and low-pressure centrifugal chillers. This article explains when to use R417a, R454C, or R123.
R417a — a drop-in R-22 replacement
Air-con and refrigeration units still on R-22 face the same problem: R-22 is phasing out (import banned in Thailand from 2030) and its price rises every year. The long-term answer is a new R-32 unit — but you may not be ready to invest yet. R417a is an A1 (non-flammable) drop-in that runs on the existing R-22 system without changing the compressor or valves — a bridge that keeps the current unit going until the replacement cycle.
- Best for: existing R-22 units that must keep running 2-4 more years before replacement
- Trade-off: slightly lower COP than original R-22; check/change oil per guidance
- Alternatives: for a long-term plan, consider R407c (retrofit) or a new R-32 unit
R454C — very low-GWP A2L for new equipment
R454C is an A2L (mildly flammable) HFO/HFC blend with very low GWP, designed for new refrigeration and heat-pump equipment built for low-GWP A2L refrigerants — not a drop-in for R-410a. Unlike R454B (which targets R-410a replacement in new AC/chillers), R454C has lower GWP and different capacity, so it's for equipment that specifically calls for R454C.
- Best for: new refrigeration/heat-pump systems wanting the lowest GWP under the phase-down plan
- Caution: it's A2L — install per flammable-refrigerant requirements (charge-per-room / ventilation)
R123 — low-pressure centrifugal chillers
R123 is an HCFC specifically for large low-pressure centrifugal chillers (replacing R-11). These machines can't easily switch refrigerants, so R-123 is still supplied for servicing/recharging existing units.
- Best for: existing centrifugal chillers on R-123/R-11 — service, recharge, R-11 retrofit
- Pack: 90.8 kg drum, made-to-order
Ordering
All three are made-to-order (quote-only) — not routinely stocked like R-32/R-410a. Send (1) the grade, (2) machine model/spec, (3) volume, (4) delivery province for a quote and lead-time confirmation. See all 15 refrigerant grades on the refrigerant service page or compare R-32 vs R-410a vs R-22.
Get this guide as a reference brief (PDF)
Summary + full section list + standards cited, Saha-branded for your memo/RFQ — emailed to you too.
Questions after reading? Talk to our engineers
Tell us what you need — our engineers help you spec it right, with a real quote. No charge.
Need help with this in your facility?
Our team handles full procurement and installation for the topics covered in this article. Free quote promptly during business hours.
Another line of ours — spreadsheet tools for SMEs
Landed Cost Per Unit — Import Costing (Thai + English editions)
Know what one unit really costs once it reaches your warehouse — duty, VAT, clearance and trucking included, with the lowest price that still meets your target margin.
Frequently Asked Questions
1Can R417a really replace R-22 without changing the compressor?
+
2How is R454C different from R454B and R-410a?
+
3What equipment uses R123, and why still an HCFC?
+
4How do I order these three grades — are they in stock?
+
Comparison tables related to this article
Related content
Pick the Right Refrigerant for the Job — A Contractor's Field Guide: Charge Tables by System (Split / VRF / Chiller / Cold Room / Ice Plant / Auto) + R-22/R-404A Replacements + How to Source Cylinders Fast
Field guide for HVAC/R contractors in Thailand: choose the correct refrigerant by actual system type (residential/commercial Split & VRF, chillers, MT/LT cold rooms, ice plants, automotive, ULT) + R-22/R-404A drop-in & retrofit table + compressor oil you must change with it (MO/POE) + how to source refrigerant fast at contractor/fleet pricing.
Thailand's Air Conditioner Export Boom 2026 — How to Choose the Right Refrigerant Grade Under the Law
Thailand is a top global air-conditioner exporter and 2026 shipments are surging on the European heatwave. This article covers the export figures, why refrigerant demand is climbing, and how to choose R-32 / R-410A / R-454B correctly under the Kigali Amendment and EU F-gas rules — for technicians and factories.
Industrial Cold Room / Cold Storage: Chiller vs Freezer vs Blast Freezer + Refrigerant Selection + Cooling Load Calculation + EN 378/GDP Standards for Thai Food, Pharma & Logistics Plants
Buyer's guide to industrial cold storage: separate chiller (+2 to +8°C) / freezer (−18 to −25°C) / blast freezer → calculate real cooling load before sizing → compare refrigerants R-449A/R-448A/R-290/R-744/NH3 → choose PIR panel thickness → contractor checklist + EN 378/ISO 5149/GDP/HACCP standards for plants in Thailand.
Very-Low / Ultra-Low Temperature Refrigerant Retrofit — Replacing R-13B1 / R-503 / R-13 in Freeze Dryers & Cascade Systems with R-508B, Done Right
A guide to very-low / ultra-low temperature (VLT/ULT) refrigerant retrofits for freeze dryers (lyophilizers), environmental chambers, blast freezers and cascade systems in Thailand: why R-13B1 (halon), R-503 and R-13 (CFC) are obsolete/unobtainable, the modern replacement R-508B across −40 to −80°C, the most-missed core of the job — changing compressor oil (mineral/AB → POE) and low-temperature oil return, how glide/azeotrope affects charging and the TXV, retrofitting both stages of a cascade, the correct procedure (recover → flush → change drier/seals → deep vacuum < 500 micron → charge by weight → pulldown), and why moisture is the deadly enemy at ULT — plus the high GWP of R-508B/R-23, lower-GWP options, and refrigerant import licensing via Thailand's DIW under Montreal/Kigali obligations.