Sahawatthanakit (1988) Co., Ltd.
SAHAWATTHANAKIT(1988) · Make It Smart
Knowledge Base Search

Search

13 results for "ANSI MH16.1"

Insights · 12

Racking Inspection Checklist — ANSI MH16.1

Annual inspection guide for warehouse pallet racking systems. Covers pre-inspection checklist, ANSI MH16.1 damage acceptance criteria, beam deflection limits, anchor torque, plumb tolerance, and a Green/Amber/Red decision table.

titledescriptiontags

Warehouse Racking Standards in Thailand — TIS 1227 / 1479 plus AS 4084 / EN 15512 / ANSI MH16.1

Thai contractors buy pallet racking without asking which code it was engineered to. TISI has not issued a dedicated TIS for racking systems, but the steel itself should comply with TIS 1227 / TIS 1479, and the rack as a system should follow AS 4084, EN 15512, or ANSI MH16.1. Here's how the two layers fit together.

titledescriptiontags

Selecting an Industrial Process Pump + Preventing Cavitation (NPSH): Centrifugal vs Positive Displacement, BEP, and VFD Energy Savings per ANSI/HI–ISO for Thai Plants

Buyer's guide to industrial process pumps: differentiate Centrifugal vs Positive Displacement → calculate NPSHa to prevent cavitation → operate within BEP (70–120%) → cut electricity with VFD (Affinity Laws) → supplier checklist + ANSI/HI–ISO 13709/API 610/API 682 standards for plants in Thailand.

titledescriptiontags

Eyewash + Safety Shower — ANSI Z358.1 Standard and Installation Locations for Chemical Plants

Guide to selecting and installing Emergency Eyewash + Safety Shower per ANSI Z358.1-2014 — 10-second reach from the hazard, minimum flow rate, water temperature, weekly + annual testing

titledescriptiontags

Selective vs Drive-In vs Push-Back Pallet Racking — Choosing by SKU velocity, footprint cost, and design code

The three main pallet racking systems trade off very differently: Selective offers 100% pallet selectivity but the lowest density, Drive-In adds 40-60% density at the cost of LIFO and pick speed, Push-Back gains 50-100% density with single-aisle access. This article compares all three under ANSI MH16.1-2023, FEM 10.2.07, and EN 15512.

descriptiontags

Seismic Design of Storage Racks — DPT 1311, ASCE 7-22, FEM 10.2.08 for Warehouses in Thailand

A guide to seismic design of pallet racking in Thailand: DPT standard 1311-50, ASCE/SEI 7-22, FEM 10.2.08 / EN 16681, ANSI MH16.1-2023, Bangkok soft-soil amplification, base plate + anchor + bracing, and what government TORs require.

description

Warehouse & Distribution Center (DC) Fit-Out and Maintenance Field Guide — Select Racking to AS 4084/EN 15512 · Epoxy/PU Floors · Steel Corrosion Protection · Rooftop Solar · Forklift Oils · Cold Storage · Safe Hot Work + How to Lock In Project Material Pricing

Field guide for warehouse and distribution-center (DC) owners and maintenance teams: plan the whole building by function — choose a racking system (Selective/Drive-In/Push-Back/Cantilever) to AS 4084/EN 15512, design for seismic loads (DPT 1311/ASCE 7), guard rack uprights and inspect annually per EN 15635, coat floors (epoxy/PU/PU-cement) to the load, protect steel from corrosion, put solar on the roof only after a structural load assessment, select forklift/MHE hydraulic-gear-grease oils, run cold storage, and control hot work during rack install/expansion per NFPA 51B — plus how to standardize materials to lock project pricing and delivery.

description

When Is R-134a Phased Out? The Kigali Amendment Timeline and Replacement Plan for Thailand

A guide to the R-134a phase-down timeline: why R-134a wasn't banned under the original Montreal Protocol but falls under the Kigali Amendment (HFC phase-down), Thailand's HFC quota reduction schedule (DIW), EU F-Gas + MAC Directive, replacements R-1234yf (automotive) and R-513A/R-1234ze (chillers), plus a transition plan for factories and vehicles in Thailand.

description

Glycol Chiller vs DX Cooling for Food Plants — Choosing by ASHRAE 90.1 / Thailand BEC

Comparing two cooling architectures for food processing: DX (Direct Expansion) where refrigerant evaporates directly in the coil, versus a Glycol Chiller secondary loop using propylene glycol — covering refrigerant charge limits per ASHRAE 15 / EN 378, food-safety PG vs EG, energy performance per ASHRAE 90.1 / BEC, glycol concentration selection, and how to match the system to Thai food plant requirements.

description

Hot Work Permit OSHA 1910.252 + NFPA 51B — Flow and Documents Thai Factories Need

Hot Work Permit guide per OSHA 1910.252 + NFPA 51B + AWS F4.1 + ANSI Z49.1 — flow chart, signature requirements, fire watch duration, fire prevention checklist, application to Thai factories

description

Welding Blanket FM 4950 Class A vs B vs C — How to Choose per Hot Work Permit NFPA 51B

Comparing the three ANSI/FM 4950 types — Welding Curtain, Welding Blanket, Welding Pad — temperature ratings, application scenarios, service life, and NFPA 51B / OSHA 1910.252 requirements for work in Thailand

description

LOTO Lockout/Tagout for Welding and Cutting — OSHA 1910.147 and Its Application in Thailand

Lockout/Tagout (LOTO) guide per OSHA 1910.147 + ANSI Z244.1 for hot work welding and cutting in Thai factories — 6 steps, equipment, training, audit, and links to NFPA 51B

description