Galvanic vs Impressed CurrentCorrosion protection — which system?

The two cathodic protection principles used in Thailand — sacrificial anode vs DC rectifier. Full spec table + decision tree + ISO 12696 / NACE / DNV standards

In short — choose by size + budget

Galvanic = small projects, no power. ICCP = large infrastructure with electricity available.

Plug-and-play

Galvanic (Sacrificial)

  • No electricity — the EMF drives Zn/Al/Mg to corrode instead of the steel
  • Low capex — starts from ฿500K
  • Near-zero OPEX — just swap anodes every 5-10 years
  • Self-limiting — no stray-current risk
  • Suits seawater + wet conditions + small-to-medium structures
Best for

Jetties < 1 km, sheet piling, vessel hulls, reinforced-concrete buildings, short buried pipelines

Industrial scale

Impressed Current (ICCP)

  • DC rectifier drives current at any resistivity
  • Inert anode (MMO/Pt) lasts 20-50 years
  • Remote monitoring 24/7 via Modbus/SCADA
  • Output adjustable for seasonal change
  • Suits large infrastructure
Best for

Pipelines > 10 km, bay-crossing bridges, offshore platforms, dry-soil tank farms

Decision tree — 5 questions

1How large is the area / structure?
Galvanic
Small-medium (< 1,000 m² of wet steel)
ICCP
Large (pipeline, bridge, platform)
2Soil resistivity?
Galvanic
Low (< 5,000 Ω·cm) — seawater / wet
ICCP
High (> 10,000 Ω·cm) — dry soil
3Power available 24/7?
Galvanic
No — remote location
ICCP
Yes — grid power accessible
4Budget?
Galvanic
< ฿2M
ICCP
> ฿2M + electricity ฿80K-200K/yr
5Monitoring requirement?
Galvanic
Manual quarterly OK
ICCP
Real-time remote required

12-item comparison table

ItemGalvanicImpressed Current
PrincipleSacrificial anode (Zn / Al / Mg) corrodes instead of the steel — driven by the EMF differenceDC power supply drives current from an inert anode (MMO/Pt/HSCI) into the environment
PowerNo electricity (self-powered)Needs a DC rectifier + AC supply 24/7
Current output (mA)Low-medium: 10-50 mA/anodeHigh: 100-50,000 mA per system
Anode lifetime5-25 years (sacrificial = consumed)20-50 years (inert anode)
Soil/water resistivity (Ω·cm)Suits <5,000 (seawater, wet)Works across the full range incl. dry soil 10,000+
Initial capex (medium project)฿500K-฿2M฿2M-฿8M (rectifier + remote monitoring)
OPEX (per year)Very low — anode swap every 5-10 yearsElectricity + rectifier maintenance ฿80K-฿200K/yr
MonitoringManual check every 6-12 monthsReal-time remote (Modbus/SCADA)
Risk of stray currentLow (self-limiting)High — needs interference testing + bonding
Suitable forSmall-medium · short-life · simple environmentsLarge infrastructure · long-life · variable resistivity
StandardsISO 12696, ASTM B418, NACE SP0387, DNV-RP-B401ISO 15589-1/2, NACE SP0169, EN 12954, DNV-RP-B101
Real-world exampleJetties, sheet piling, small vessel hulls, steel-reinforced buildingsBay-crossing bridges, pipelines 10+ km, offshore platforms

Need a site survey + spec recommendation?

Send photos of the structure + soil resistivity (if available) → our engineers promptly propose a system + budget

FAQ

Common Questions

Q1.When to choose galvanic vs impressed current (ICCP)?+
By structure size + soil/water resistivity: • Galvanic (sacrificial anode): small-medium structures, seawater, resistivity <50 Ω·m • Impressed Current (ICCP): large structures, long pipelines, dry soil >100 Ω·m Standards: NACE SP0169 + ISO 12696:2022.
Q2.How do initial vs maintenance costs compare?+
25-year TCO (1,000 m² structure): • Galvanic: capex ~฿300K + maintenance ฿20K/yr × 25 ≈ ฿800K • ICCP: capex ~฿800K + maintenance ฿50K/yr × 25 ≈ ฿2,050K Galvanic is half the lifetime cost — but anodes need replacement every 10-15 years.
Q3.What's the anode service life?+
Depends on current demand + environment: • Zinc anode (ASTM B418 Type II): 15-25 years in seawater • Magnesium anode (ASTM G-97): 5-15 years in fresh water • Aluminum anode (DNV-RP-B401): 20-30 years in seawater • ICCP MMO anode: 20+ years (requires continuous DC power)
Q4.Which standards apply for Thai government TOR?+
EGAT / SRT / MEA / PEA + port/bridge projects commonly cite: • ISO 12696:2022 (concrete reinforcement) • NACE SP0169 (pipeline external corrosion) • ASTM B418 (zinc), B843 (magnesium), B26 (alloy) • TIS 3029-2563 (zinc anode for cathodic protection)
Q5.Does ICCP need continuous power?+
Yes — ICCP requires DC power supply 1-50 A continuously + maintenance every 6 months (rectifier check, reference electrode calibration). Galvanic needs no power — uses anode electrochemical potential. Remote / offshore / unreliable-power sites favor galvanic.
Free advice · a prompt, real quotation during business hours

Still not sure which one fits your job?

Tell us the job in a line — a Sahawatthanakit engineer checks the right rust-protection systems for you free, with a prompt quotation during business hours.