Sahawatthanakit (1988) Co., Ltd.
SAHAWATTHANAKIT(1988) · Make It Smart
Refrigerant lifecycle compared

Recovery vs Recycle vs ReclaimHandle used refrigerant legally + cost-effectively

The 3 Rs of refrigerant under EPA Section 608 + Kigali Amendment + TIS 3008 — Recovery (mandatory), Recycle (same-system), Reclaim (AHRI 700 — save 30-60% vs virgin)

In short — which route?

The 3 Rs are not alternatives — they are steps. Every service starts with Recovery → then decide Recycle (same-system) vs Reclaim (AHRI 700 spec, resellable). Reclaim has the best ROI if you remove 50+ kg/yr

Mandatory every time (EPA + TIS)

Recovery

  • No venting to atmosphere — Thai law
  • Requires a recovery machine + DOT-39 cylinder
  • Done on site — 30 min to 2 hrs
  • Output not yet usable — must be reclaimed
Best for

Every time refrigerant is removed (service, retrofit, decommissioning) — step one of all 3 Rs

Same-system reuse

Recycle

  • On-site filter-drier + oil separator
  • Does not meet AHRI 700 — same system only
  • Equipment costs several times more than recovery
  • No resale / no use in new systems
Best for

Service contracts returning refrigerant to the same unit, same-system retrofits, reducing downtime

AHRI 700 — best ROI

Reclaim

  • Meets AHRI 700 on every parameter
  • Save 30-60% vs virgin
  • Can be resold / used in new systems
  • ESG/CSR + Kigali compliance
Best for

Large plants removing 50+ kg/yr of R-22 + R-410A, decommissioning projects, fleet maintenance

Full spec comparison table

ItemRecoveryRecycleReclaim
DefinitionPump refrigerant out of the system into a storage cylinderOn-site cleaning (filter-drier + oil separator)Lab purification through multi-stage distillation + filtration
Resulting purity**Mixed contaminants** — cannot be reused directlyReduced moisture + particulates — **does not meet AHRI 700****Meets AHRI 700 on every parameter** — equivalent to virgin
AHRI 700 compliance✗✗ Partial✓ Every parameter
ReuseMust be reclaimed before reuse**Same system only** — no resaleResale + use in new systems + warranty-covered
Equipment usedRecovery machine (brands technicians commonly use, e.g. Yellow Jacket / CPS / Inficon — we do not sell them) + DOT-39 cylinderRecycle machine (e.g. Robinair / Bacharach) + multi-stage filterIndustrial distillation column + GC analyzer at an EPA-certified facility
Time required30 min - 2 hrs per system (depends on charge)Inline with recovery — +20-40% timeOff-site 7-14 days (queued at the facility)
CostMachine + DOT-39 cylinder — quote-onlyMachine + filter cartridges — quote-only (several times the investment of recovery)Charged per kg (pickup-delivery-COA) — quote-only
EPA Section 608 mandatory✓ **Mandatory every time** refrigerant is removed — no venting to atmosphereOptional — depends on refrigerant condition + use caseMandatory for resale / use in new systems — must go through an EPA-certified facility
TIS 3008-2562 (Thailand)References EPA 608 — no venting of any HFC + HCFCPermitted for same-system reuse onlyMandatory for HFC resold in the Thai market
Cost saving vs virgin0% (not yet usable)Same as virgin (refurbished within the same system)**Save 30-60%** depending on refrigerant type
Applicable refrigerantsAll types — R-22, R-32, R-410A, R-134a, R-404a, R-1234yfAll of the same types — but never mix (cross-contamination)All HFC + HFO with a reclamation facility (R-22 phasing out)
Sahawatthanakit's roleSupplies refrigerant for recharge + advises retrofit paths per manufacturer documentationSame — running the equipment is the job of contractors/technicians with the gearSame — reclaim must go through a licensed facility

References: EPA 40 CFR Part 82 (Section 608 — Stratospheric Ozone Protection), AHRI Standard 700-2019 (Specifications for Refrigerants), Kigali Amendment to Montreal Protocol (2019 ratification), TIS 3008-2562 (TIS quality standard for HFC), Department of Industrial Works (DIW) refrigerant management licensing. Thai market average prices May 2026 — fluctuate with Kigali quotas every 2-3 years

Refrigerant removed — which grade goes back in?

We are a refrigerant supplier and do not perform recovery/reclaim ourselves — but tell us the grade + quantity (kg/cylinders) + destination and we send live pricing, availability and MSDS, plus retrofit-path advice per manufacturer documentation if you are changing grade

Related comparisons

Decide with confidence — compare from several angles

Read the related comparison tables — full specs, real prices, and a recommendation for each use.

FAQ

Common Questions

Q1.Recovery vs Recycle vs Reclaim — what are the 3 Rs of refrigerant?+
**Three levels of used-refrigerant handling** per EPA Section 608 — differ by post-processing purity: • **Recovery** — extract refrigerant from system into a recovery cylinder (DOT-39 or DOT-4BW) **without any cleaning**. Uses a recovery machine (Yellow Jacket / CPS / Inficon) pulling vacuum to 250-1,000 microns. **Output = refrigerant mixed with contaminants** — must be reclaimed before reuse • **Recycle** — on-site processing through filter-drier + oil separator + acid scavenger. **Partial cleaning** (reduces moisture, removes particulates, separates compressor oil) but **does NOT meet AHRI 700 spec**. **Same-system reuse only** — cannot resell or use in new systems • **Reclaim** — sent to an EPA-certified reclamation facility for multi-step distillation + chemical filtration. **Passes every AHRI 700 spec metric** (purity ≥ 99.5% + moisture ≤ 10 ppm + acid ≤ 1 ppm + non-condensables ≤ 1.5%). **Equivalent to virgin refrigerant** — can be resold and used in new systems **EPA + Thai TIS 3008 rules:** Every refrigerant removed from old equipment must be recovered (venting to atmosphere = illegal) → can recycle for same-system reuse, but resale/new-system use requires reclaim
Q2.What is AHRI 700 — why does it matter?+
**AHRI Standard 700 (2019)** = Air-Conditioning, Heating & Refrigeration Institute spec for refrigerant purity. **Sets minimum quality** allowed on market: • **Air (non-condensables)** ≤ 1.5% by volume (in vapor phase at 25°C) • **Water** ≤ 10 ppm by mass • **Acidity** ≤ 1 ppm by mass (as HCl equivalent) • **High-boiling residue** ≤ 0.01% by volume • **Particulates** — none visible at 50× magnification • **Other refrigerants (cross-contamination)** ≤ 0.5% by mass **Enforcement:** EPA Section 608 (USA) uses AHRI 700 as the benchmark for reclaim certification. Thailand's TIS 3008-2562 (HFC quality spec) cites every AHRI 700 parameter. **If refrigerant fails AHRI 700** → compressor damage, lower efficiency, system trips, warranty void
Q3.How much do I save with reclaimed vs virgin?+
**Savings 30-60% per kg** depending on refrigerant type and current market — refrigerant is a world-market commodity, so we quote live per deal rather than publish a price table: • **R-22** widest gap, **~45-50%** (virgin keeps tightening under phase-out) • **R-410A** **~35-40%** • **R-134a** **~30-38%** • **R-32** — **reclaimed market still limited** (R-32 newer, virgin supply still ample) **ROI for 1,000-ton cooling factory (~500 kg refrigerant charge):** • Service maintenance over 5 yrs = ~150 kg cumulative removed • Using reclaim instead of virgin cuts roughly a third off that refrigerant spend • Reclaim is charged per kg by the service provider / licensed plant (pickup → EPA-cert lab → return) — **Sahawatthanakit does not take on that work**; we supply the refrigerant that goes back in **Bonus benefits:** lower carbon footprint + ESG/CSR reporting + reduced virgin demand (matters to ESG investors 2025+)
Q4.How do TIS 3008 + Kigali Amendment affect Thailand?+
**Kigali Amendment to Montreal Protocol (2019)** — Thailand signed onto HFC phase-down (R-410A, R-134a, R-32): • **2024:** baseline ~125 million tons CO₂e/yr • **2029:** reduce 10% from baseline (-12.5 MtCO₂e) • **2035:** reduce 30% • **2040:** reduce 50% • **2045:** reduce 80% **TIS 3008-2562 (Thai HFC quality standard for air conditioning)** mandates: 1. Every HFC sold in Thailand must have a COA per AHRI 700 — off-spec sales prohibited 2. **Reclamation infrastructure** — Department of Industrial Works (DIW) licenses registered reclamation facilities (~12 active in Thailand as of May 2026) 3. **Reporting** — facilities using HFC > 200 kg/yr must report annual usage to DIW + Pollution Control Department **Price impact:** Kigali phase-down drives HFC prices up 15-30% every 2-3 years (quota cuts) → **reclaim ROI improves yearly**. HFOs (R-1234yf, R-1234ze) cost 4-6× more but aren't covered by Kigali → premium choice for new systems
Q5.Does Saha handle recovery + reclaim service — is DIW involvement needed?+
**Straight answer: no — we do not perform recovery or reclaim ourselves.** Sahawatthanakit is a **refrigerant distributor**, not an on-site service contractor or a reclamation plant. • **What we do:** supply refrigerant for the recharge after service/retrofit (15 grades) · MSDS/COA with every lot · **advise the retrofit path from the manufacturers' own documents** (e.g. R-12/R-500 → R-134a requires POE oil + new filter drier per DuPont ART-37; R-502 → R-404A per Copeland AEB 94-15) • **What needs someone else:** on-site recovery requires a technician with recovery equipment and DOT-39 cylinders · reclaiming to AHRI 700 spec must go through a licensed facility — we do not warrant that work on anyone's behalf • **Why we draw the line:** venting refrigerant is illegal, and topping up with a different grade while skipping the retrofit steps is what destroys compressors — so we give you the correct procedure rather than take on work we don't do **Quote request:** tell us the grade + quantity (kg/cylinder) + delivery point → we send live pricing, availability and MSDS.
Free advice · a prompt, real quotation during business hours

Still not sure which one fits your job?

Tell us the job in a line — a Sahawatthanakit engineer checks the right refrigerants for you free, with a prompt quotation during business hours.